Received: 8 February 2024 | Accepted: 12 June 2024 DOI: 10.1111/eve.14025
R E V I EW A R T I C L E
Use of transrectal transducers in abdominal ultrasonography of horses: A review
Jean- Yin Tan 1 | Hanna Haardt 2
1 Faculty of Veterinary Medicine , University of Calgary , Calgary , Alberta , Canada 2 Department of Large Animal Surgery, Anaesthesia and Orthopaedics , Ghent University , Merelbeke , Belgium
Correspondence: Jean- Yin Tan Email:
jeanyin.tan@ucalgary.ca
Funding information University of Calgary Faculty of Veterinary Medicine Internship Research Fund
Summary Abdominal ultrasonography is an important diagnostic tool in the evaluation of colic, yet primary care equine veterinary practitioners are often limited by availability and access to low- frequency (2–5 MHz curvilinear array or sector) abdominal transducers. Use of high- frequency (5–10 MHz linear array) transrectal transducers has not previously been compared with use of abdominal transducers for transcutaneous abdominal ultrasonog- raphy. One recent pilot study established that there was no significant difference in organ detection by the two transducers on the right side of the equine abdomen, but the stom- ach, liver and kidney on the left side were less likely to be detected using the transrectal transducer in healthy horses. A clinical study found that the transrectal transducer can be used successfully using the FLASH protocol in horses presenting with colic, with high- quality images that detected abnormalities of the peritoneal fluid, small intestine and large intestine. The transrectal transducer had decreased visualisation of the stomach and left kidney and was less likely to detect pathology surrounding these organs. This is the first series of studies to evaluate use of transrectal transducers in abdominal ultra- sonography of the horse, a tool that is readily accessible to the field practitioner.
K E YWORDS horse , colic , diagnostic imaging , probe , ultrasound
BACKGROUND
Colic is a common condition in horse, with an incidence of 4.2 events/100 horses per year. It is a leading cause of death among horses, second only to old age (USDA, 2001 ). Abdominal ultraso- nography is an important diagnostic tool during colic evaluation and identifies small intestinal obstruction, determines intestinal motility and has a role in the accurate definitive diagnosis of lesions of the small and large intestine (Beccati et al., 2011 ; Scharner et al., 2015 ). The equine abdomen is traditionally scanned using a 2–5 MHz
curvilinear array or sector transducer, colloquially known as the ‘ab- dominal probe’ (and referred hereinafter as ‘abdominal transducer’) yet few primary care equine veterinary practitioners have access to this transducer. While this may vary based on geographic location,
only 8% of ultrasound machines purchased for use in equine prac- tice in Canada from 2016 to 2021 included an abdominal transducer (Walklate, 2021 ). In addition, the use of a wireless 3.5 MHz curvi- linear probe for the examination of colic cases in the field has re- cently been described (Corrie et al., 2024 ). Meanwhile, practitioners commonly use 5–10 MHz linear array ultrasound transducers for reproductive examinations (colloquially known as the ‘rectal probe’ and referred hereinafter as ‘transrectal
transducer’). Given that
colic accounts for 1/3 of afterhours calls in primary care and only 1/5 of these cases may be hospitalised, of which 81% subsequently undergo abdominal ultrasound, field ultrasonography may assist with rapid decision- making in the field (Bowden et al., 2020 ; Burrell (nee Lightfoot) et al., 2023 ; Proudman et al., 2002 ; Scantlebury et al., 2014 ).
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. © 2024 The Author(s). Equine Veterinary Education published by John Wiley & Sons Ltd on behalf of EVJ Ltd.
Equine Vet Educ. 2024;36:603–606.
aaep.org/wiley-redirect | 603
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92